Solar DC/AC Submersible Pump & Cable

  • ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel
  • ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel
  • ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel
  • ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel
  • ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel
  • ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel
  • ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel
  • ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel
ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel

ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel

  • Conductor: Bare Copper
  • Insulation: Flexible EPR/NBR/PP/Polyimide-F46
  • Outer Jacket: Flexible EPR/EPDM/NBR Rubber or lead tape
  • Standard:IEEE1017, IEEE 1018, IEEE1019, API RP 11S5, API RP 11S6
  • Product description: ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel Conductor: Rigid solid copper or bare copper Conductor Insulation: Flexible EPR/NBR/PP/Polyimide-F46 Insula
  • INQUIRY

ESP Armoured Rubber Submersible Oil Pump Cable EPR/NBR/PP/Polyimide Insulated Wire Kabel



Application & Usage

The products of the flat/round submersible pump cable are suitable for electric submersible pumps (water submersible and halogen elements) with a rated voltage of 1.8/3Kv, 3.6/61Kv, 1/35 KV KV and below. The bottom end of the round submersible pump cable immersed in oil is connected to the submersible motor, and the upper end of the flat/round submersible pump cable not oil immersed is connected to the distribution box on land. And the long-term working temperature of the conductor is 120℃.


Cable Structures:

Conductor: Rigid solid copper or bare copper Conductor

Insulation: Flexible EPR/NBR/PP/Polyimide-F46

Insulation Color:3 core: Black,white,Green.

Outer Jacket: Flexible EPR/EPDM/NBR Rubber or lead tape.

Jacket Color: Black or metal origin or as per client’s request.


Executed Standard:

IEEE1017, IEEE 1018, IEEE1019, API RP 11S5, API RP 11S6


Advantage & Characters

The cable has the excellent ability of oil-resistance, heat-resistance, and corrosion-resistance.


Sizes & Data Sheeets

Cable Code for ESP Armoured Rubber Submersible Oil Pump Cable Wire Kabel
Cable Code type Description Max. operation temperature ºC Cable Conductor sizes mm2 & AWG/MCM
QYPN PP insulated and NBR jacked, galvanized steel tape interlocked armour, cable for submersible oil pump 96 10,13,16,20,33,42 #6AWG~#1AWG
QYPNY PP insulated and NBR jacked, galvanized steel tape interlocked armour, round cable for submersible oil pump 96 10,13,16,20,33,42 #6AWG~#1AWG
QYEN EPDM/EPR insulated and NBR jacked galvanized steel tape interlocked armour, for submersible oil pump 140 10,13,16,20,33,42 #6AWG~#1AWG
QYENY EPDM/EPR insulated and NBR jacked,galvanized steel tape interlocked armour,round submersible oil pump cable 140 10,13,16,20,33,42 #6AWG~#1AWG
QYEE EPDM/EPR insulated and jacked,galvanized steel tape interlocked armour,submersible oil pump cable 175 10,13,16,20,33,42 #6AWG~#1AWG
QYEEY EPDM/EPR insulated and jacked,galvanized steel tape interlocked armour,round submersible oil pump cable 175 10,13,16,20,33,42 #6AWG~#1AWG
QYEQ EPDM/EPR insulated and lead jacked,galvanized steel tape interlocked armour,submersible oil pump cable 204 10,13,16,20,33,42 #6AWG~#1AWG
QYYEQ Polyimide-F46 composite film and EPDM/EPR insulated,lead jacked, galvanized steel tape interlocked armour, submersible oil pump cable 232 10,13,16,20,33,42 #6AWG~#1AWG
QYYEEY Polyimide-F46 composite film and EPDM/EPR insulated, EPDM/EPR jacked, galvanized steel tape interlocked armour, round submersible oil pump cable 204 10,13,16,20,33,42 #6AWG~#1AWG

QYEQ ESP CABLE SPECIFICATION AND PARAMETERS
SI.No Voltage Rating (kv) Conductor Size Nominal Conductor Diameter Insulation Outside Diameter Lead Outside Diameter Armor Type Nominal Cable OD Nominal Weight (Approx.) kofan
AWG inches mm Inchts mm Inches mm Inches mmxmm Ibs/1000ft kg/km
1 4kv 16 0.18 4.62 0.33 8.42 0.41 10.42 galvanized steel Tape 0.5X1.4 13x36 1485 2211
2 4kv AWG4 20 0.20 5.19 0.35 add 0.43 10.59 galvanized steel Tape 0.6x1.5 14*38 1640 2442
3 4kv AWG2 33 0.26 6.54 0.41 10.34 0.49 12.34 galvanized steel Tape 0.6x17 15x43 2093 3116
4 4kv AWG1 42 0.29 7.35 0.44 11.15 0.52 13.15 galvanized steel Tape 0.6x13 16x45 2380 3544
5 5kv 16 0.18 4.62 0.36 9.22 0.44 11.22 galvanized steel Tape 0.5X1.5 13x38 1619 2410
6 5kv AWG4 20 0.20 5.19 0.39 9.79 0.46 11.79 galvanized steel Tape 0.6X1.6 14*40 1834 2730
7 5kv AWG2 33 0.26 6.54 0.44 11.14 0.52 13.14 galvanlzsd steel T ape 06x1.8 15*45 2230 3320
8 5kv AWG1 42 0.29 7.35 0.47 11.95 0.55 13.95 gaivanted steel Tape 0.6x1.9 16x47 2586 3850
QYEQEY
SI.No Voltage Rating (kv) Conductor Size Nominal Conductor Dlamater Insulation Outside Dlamotar Nominal Jacket Diameter Armor Type Nominal Cable OD Nominal Weight (Approximate)
AWG mm* Inches mm Inches mm Lead OD Inches Lead OD mm Jacket OD Inches JacketOD mm Inches mm lbs/ 1000ft
1 4kv 16 0.18 4.62 0.33 842 0.41 10.42 1.08 27.5 Full galvanized steel Tape 1.26 32 1398 2082
2 4kv AWG4 20 0.20 5.19 0.35 8.99 0.43 10.99 1.13 28.7 Full galvanized steel Tape 1.34 32 1611 2399
3 4kv AWG2 33 0.26 6.54 0.41 10.34 0.49 12.34 1.25 31.7 Full galvanized steel Tape 1.42 36 2096 3120
4 4kv AWG1 42 0.29 7.35 0.44 11.15 0.52 13.15 1.31 33.4 Full galvanized steel Tape 1.50 38 2223 3310
5 5kv 16 0.18 4.62 0.36 922 0.44 1122 1.15 29.2 Full galvanized steel Tape 1.30 33 1540 2293
6 5kv AWG4 20 0.20 5.19 0.39 9.79 0.45 11.79 1.20 30.5 Full galvanized steel Tape 1.38 35 1731 2577
7 5kv AWG2 33 0.26 6.54 0.44 11.14 0.52 13.14 1.31 33.4 Full galvanized steel Tape 1.46 37 2133 3176
8 5kv AWG1 42 0.29 7.35 0.47 11.95 0.55 13.95 1.38 35.1 Full galvanized steel Tape 1.54 39 2395 3566

QYYEQEY ESP CABLE SIZES AND DATA SHEET
NO. Voltage Conductor Size Conductor OD Insulation OD Nominal Jacket Diameter Armour Type Nominal Cable OD Nominal Weight {Approximate)
Rating (kv) AWG mm2 Inches mm Inches mm Lead Outside Diameter Jacket OD Inches mm lbs/ 1000ft kg/km
Inches mm Inches mm
1 4kv 16 0.18 4.62 0.34 8.52 0.41 10.52 1.09 27.7 Full galvanized steel Tape 1.26 32 1552 2310
2 4W AWG4 20 0.20 5.19 0.36 9.09 0.44 11.09 1.14 29.0 1.34 34 1799 2678
3 4kv AWG2 33 0.26 6.54 0.41 10.44 0.49 12.44 1.26 31.9 1.42 36 2052 3055
4 4kv AWG1 42 0.29 7.35 0.44 11.25 0.52 13.25 1.32 33.6 1.50 38 2391 3560
5 5kv 16 0.18 4.62 0.37 9.32 0.45 11.32 1.16 39.5 1.34 34 1673 2491
6 5kv AVVG4 20 0.20 5.19 0.39 9^9 0.47 11.89 1.21 30.7 1.42 36 2016 3002
7 5kv AWG2 33 0.26 6.54 0.44 1124 0.52 13.24 1.32 33.6 1.50 38 2223 3310
8 5kv ZWVG1 42 0.29 7.35 0.47 12.05 0.55 14.05 1.39 35.3 1.57 40 2529 3766

QYYEQ
No. Voltage Rating (kv) Cond.Size Nominal Cond. OD Insulation OD Lead OD Armor Type Nominal Cable OD Nominal Weight (Approx.) IbsMOOOft kg/km
Inches mm Inches mm Inches mm Inches mm Inches mm x mm lbs/ 1000ft kg/km
1 4kv 16 0.18 4.62 0.33 842 0.41 10.42 Full galvanized steel Tape 0.5x1.4 13x36
2 4kv AWG4 20 0.20 5.19 0.35 8.99 0.43 1039 0.6X1.5 14*38 1655 2464
3 4kv AWG2 33 0.26 6.54 0.41 10.34 0.49 1234 0.6x1.7 15x43 2111 3143
4 4kv AWG1 42 0.29 7.35 0.44 11.15 0.52 13.15 0.6x1.8 16x45 2401 3575
5 5kv 16 0.18 4.62 0.36 922 0.44 1122 0.5x1.5 13x38 1632 2430
6 5kv AWG4 20 0.20 5.19 0.39 9.79 0.46 11.79 0.6X1.6 14x40 1848 2752
7 5kv AWG2 33 0.26 6.54 0.44 11.14 0.52 13.14 0.6x1.8 15*45 2249 3348
8 5kv AWG1 42 0.29 7.35 0.47 11.95 0.55 1355 0.6x1.9 16x47 2607 3881
Note: Armor material can choose stainless steel tape or monel tape, this according to customers requirement.


AMPACITY RATING AND VOLTAGE DROP CHART for ESP Armoured Rubber Submersible Oil Pump Cable


Scan the qr codeClose