Energy Storage Cable

  • 600V Energy Storage Cable Wire Single Insulation DC kabel 2 PfG 2693 TUV Approved kablo
  • 600V Energy Storage Cable Wire Single Insulation DC kabel 2 PfG 2693 TUV Approved kablo
  • 600V Energy Storage Cable Wire Single Insulation DC kabel 2 PfG 2693 TUV Approved kablo
600V Energy Storage Cable Wire Single Insulation DC kabel 2 PfG 2693 TUV Approved kablo600V Energy Storage Cable Wire Single Insulation DC kabel 2 PfG 2693 TUV Approved kablo600V Energy Storage Cable Wire Single Insulation DC kabel 2 PfG 2693 TUV Approved kablo

600V Energy Storage Cable Wire Single Insulation DC kabel 2 PfG 2693 TUV Approved kablo

  • Conductor: Bare Copper
  • Insulation: XLPE
  • Sheath: None
  • Rated voltage: 600VDC
  • Product description: 600V Energy Storage Cable Wire Single Insulation DC kabel 2 PfG 2693 TUV Approved kablo Conductor: EN60228Class5soft annealed stranded copper Insulation: Electron-beamcross-linked materials with RoH
  • INQUIRY

600V Energy Storage Cable Wire Single Insulation DC kabel 2 PfG 2693 TUV Approved kablo




Approvals

TUV Certification 2PfG 2693/06.19 all color

4.0-70mm²


Technical data

Conductor: EN60228Class5soft annealed stranded copper

Insulation: Electron-beamcross-linked materials with RoHS compliance

Rated voltage: 600VDC,

Test voltage: 600VDC=3000V, 5Min.,

Ambient temperature: -40Cup to+125℃

Insulation volume resistivity: 1x 1011q.cm

Low temperature impact test: -40±2°C*16h,

compliance with the EN 60811-506 standard,

Low temperature bending test: (Cable outer diameter≦12.5mm) -40±2℃*16H, in accordance with EN 60811-504; without cracking,

Shrinkage test: ComplywithEN60811-503,200℃, 1H,shrinkage 2%

Compatibility test: 10daysat135±2℃,Tensile strength Median,

min.5.0N/mm 2.Variation-30%:

Elongation at break Median, min.200%, Variation-30%,

Continuous aging in oven: compliancewiththeEN60811-401

standard, 40±2℃/240H, Values to be obtained for tensile

strength, Variation, max.±20%, Values to be obtained for elongation

at bred.Variation, max.±20%

Acid resistance test: ISO6722-1(Indoor)

Halogen content test; EN 50525-1ANNEXB(Indoor)

Smoke density(Suitable for low smoke without halogen cable) :

EN 61034-2, Light transmittance 260%;

Flame retardant: EN60332-1-2(Wholewire)

Artificial climate aging test: TUVaccreditation2PfG2693/06.19


Cross section (mm )2 Conductor constuction (n/mm) DC 600V ,ESL06Z3-K 125°C ESW06Z3-K 125°C Conductor Max. Resistance AT 20°C(Q/km)
Insulation Nominal average outer diameter (mm) Maximum outer diameter of finished Cable (mm)
Ave.Thic. (mm) Min. Thic.(mm)
4.0 56/0.285 0.50 0.35 3.70 4.20 5.09
6.0 84/0.285 0.50 0.35 4.40 4.80 3.39
10.0 497/0.16 0.60 0.44 5.90 6.10 1.95
16.0 512/0.20 0.70 0.53 7.30 7.70 1.24
25.0 798/0.20 0.70 0.53 8.60 9.40 0.795
35.0 1121/0.20 0.80 0.62 10.40 11.20 0.565
50.0 1596/0.20 0.90 0.71 12.20 13.20 0.393
70.0 2220/0.20 1.00 0.80 14.20 15.60 0.277


Scan the qr codeClose
the qr code