Twin fig-8 PV1-F 2PfG 1169 1800V DC PV solar wire cable 2-core 1.5~16mm2 kablo TUV Approved kabel
Application
Suitable for nominal DC voltage 1.5KV(Between conductor to conductor or conductor to earth) solar power system.
Double insulation, electron-beam cross-linked cables for photovoltaic powerstation Construction
Conductor.Tinned copper, according to the VDE
0295/IEC 60228, Class 5
Insulation:Polyolefincopolymerelectron-beamcross-inked
Outersheath:Polyolefincopolymerelectron-beamcross-linked
Sheath color:Black/Red/Blueoraspercustomer'srequest
Nominalvoltage:Uo/U=600/1000VAC, 1800VDC
Voltage test on completed cable:6.5kVAC, 15kVDC, 5min
Ambient temperature:-40Cup to+90°C
Max.Temperature at conductor:+120°C
The expected period of use is 25 years(Ambiet temperature:-40°Cup to+90℃)
The permitted short-circuit-temperature refer to a
period of 5sis+200°C
Bending radius:≥4XOD(OD<8mm) ; ≥6×OD(OD≥8mm)
Resistanceagainstacidandalkalinesoluton:EN60811-2-1
Coldbendingtest:EN60811-1-4
Weathering/UV-resistance:HD605/A1
O-zoneresistanceatcompletecable:EN50396
Firetest:IEC60332-1Smoke density:IEC 61034, EN 50268-2
Contentofhalogenacidgas:IEC670754-1EN50267-2-1
Material Properties/Standards
Fire-resistanceperformance:IEC60332-1
Smokeemission:IEC61034:EN50268-2
Low fire load:DIN 51900
Approvals:TUV2PfG1169/08.2007 PV1-F
Application standards:UNE 21123; UNE 20.460-5-52, UTEC 32-502
Core* Cross section 2 (N*mm ) | Conductor constuction (n/mm) | Insulation | Sheath | Cable OD. (mm) | Conductor Max. Resistance AT 20°C(Q/km) | (60°C) (A) Current earring capacity AT 60 °C (A) In air |
Ave. Thic. (mm) | Ave. Thic. (mm) | Minimum outer diameter | ||||
2*1.5 | 30/0.25 | 0.70 | 0.80 | 5.00*10.30(+0.20) | 13.70 | 30 |
2*2.5 | 49/0.25 | 0.70 | 0.80 | 5.20*10.80(+0.20) | 8.21 | 41 |
2*4.0 | 56/0.285 | 0.70 | 0.80 | 5.50*11.20(+0.20) | 5.09 | 55 |
2*6.0 | 84/0.285 | 0.70 | 0.80 | 6.20*12.60(+0.20) | 3.39 | 70 |
2*10.0 | 84/0.385 | 0.70 | 0.80 | 7.50*15.20(+0.25) | 1.95 | 98 |
2*16.0 | 128/0.40 | 0.70 | 0.90 | 9.60*19.70(+0.30) | 1.24 | 132 |
Advantages
Electron-beam cross-linked compounds
UV, ozone and hydrolysis resistant
High temperature resistant, the materials do not melt or flow
Good cold flexibity
Very long service life>25 years at 90℃
Compatible to all popular connectors
Other related cables and connectors:
Solar PV MC4 connectors, branches and lead extension wire harness.